Posts: 8,888
Threads: 320
Joined: Feb 2012
Location: Arizona/Minnesota
(04-11-2015, 08:17 PM)PixMan Wrote: Keep your eyes open and your wallet full for a deal on the Mitutoyo 293-336 digital electronic one like your 0-1" 293-348.
If my 293-345 1-2" with the ratchet thimble wasn't such a great deal, that 293-336 is what I would have.
This seems to be about the cheapest.
http://www.amazon.com/Mitutoyo-293-345-3..._title_def
I think I'll have to make do with what I have for now.
Ed
Posts: 4,683
Threads: 93
Joined: Feb 2012
Location: Perth, Australia
The following 1 user Likes Mayhem's post:
PixMan (04-12-2015)
I put together a set of S/H Starrett 436 metric mics covering 0 - 200mm. One doesn't have a lock on it but it doesn't bother me, as I take the reading before I remove the mic from the part. Come to think of it, I tend to do that with those that have locks on them as well.
Hunting American dentists since 2015.
Posts: 2,344
Threads: 53
Joined: Feb 2012
Location: Spencer MA USA
(04-12-2015, 03:20 AM)Mayhem Wrote: I put together a set of S/H Starrett 436 metric mics covering 0 - 200mm. One doesn't have a lock on it but it doesn't bother me, as I take the reading before I remove the mic from the part. Come to think of it, I tend to do that with those that have locks on them as well.
For those micrometers I have without locks or electronic displays, that's what I do most often.
One of the myriad features of the Mitutoyo Absolute digital electronic micrometers which dearly love is that "Hold" button. Get the micrometer touching just right, thumb that button and loosen the thimble to remove it from the work. Your reading is still there. Hit the Hold button again and you're back to direct reading.
Life is good.
Posts: 8,888
Threads: 320
Joined: Feb 2012
Location: Arizona/Minnesota
(04-12-2015, 03:20 AM)Mayhem Wrote: ... One doesn't have a lock on it but it doesn't bother me, as I take the reading before I remove the mic from the part. Come to think of it, I tend to do that with those that have locks on them as well.
That's easy to do with the electronic micrometers but not so easy with vernier micrometers. Or maybe I'm just unskilled at reading them.
Ed
Posts: 3,003
Threads: 51
Joined: Apr 2012
Location: Ontario
Use the lock most of the time. Rather than going by the feel of the load on the spindle, i'll get what appears to be the measurement then close the mic maybe a half thou and feel the drag as I slip it over the shaft.
Free advice is worth exactly what you payed for it.